Variable Spring Hanger and Support Terminologies

Variable Spring Part No.Categorized by spring rate.
Variable Spring SizeCategorized by load range.
Variable Spring TypeCategorized by physical shape.
Hot load / Hot setting / Operating loadThe weight the variable spring has to support while the pipe line system is in operation.
Cold load / Cold setting / Installed loadThe weight the variable spring has to support while the pipe line system is NOT in operation. This is also called pre-set load.
Movement/ TravelThe measure of a vertical travel distance of the pipe which is supported by the variable spring when the pipe line is in operation.
Movement/ Travel directionThe movement direction, either UP or DOWN of the pipe while in operation compared to its resting point (not in operation).
Spring rateLbs/in of spring travel.
Hydro-tested loadThe test which determines whether or not the variable spring will support the operating load.
Travel stopsLimit the spring travel at the top and bottom to a small percentage beyond the specified range. In addition, they prevent the spring from moving while the spring is not in operation (in pre-set mode) or in hydrostatic testing phrase.
Load flangeTop Plate on which the pipe load rests.
VariabilityThe amount of supporting load variation on horizontal piping. The percentage of variability should not exceed 25%.